Relations between contact force, bipolar voltage amplitude, and mapping point distance from the left atrial surfaces of 3D ultrasound- and merged 3D CT-derived images: Implication for atrial fibrillation mapping and ablation.


Heart Rhythm. 2015 Jan;12(1):36-43.

Relations between contact force, bipolar voltage amplitude, and mapping point distance from the left atrial surfaces of 3D ultrasound- and merged 3D CT-derived images: Implication for atrial fibrillation mapping and ablation.

Sasaki N1Okumura Y2Watanabe I1Sonoda K1Kogawa R1Takahashi K1Iso K1Nakahara S3Maruyama A4Takemura S4Hirayama A1.

BACKGROUND:

Catheter tip-derived contact force (CF) and 3-dimensional (3D) maps are key to mapping and ablation of atrial fibrillation.

OBJECTIVE:

This study sought to determine the relation between CF and 3D map surfaces.

METHODS:

We conducted a validation study of Carto-based 3D ultrasound (3D-US) and 3D-US merged with computed tomography (3D-Merge-CT)left atrium/pulmonary vein images. Under fluoroscopic guidance, 1361 mapping points (20 patients) with CFs and electrogram information were randomly acquired around the PVs.

RESULTS:

CF correlated weakly with the distance of mapping points from the 3D-Merge-CT (r = 0.27; P < .001) and 3D-US (r = 0.22; P < .001) surfaces but not with bipolar voltage (r = -0.01; P = .2400). Low CF (0-4 g) yielded points close to the 3D-US surface; moderate (5-9 g) and high CFs (10-20 g) generated points beyond the surface (0.1 ± 3.9, 1.4 ± 3.4, and 2.3 ± 3.4 mm; P < .05 for each). Low, moderate, and high CFs yielded points below, close to, and beyond the 3D-Merge-CT surface (-1.2 ± 3.7, 0.4 ± 3.0, and 1.0 ± 2.9 mm; P < .05 for each).

CONCLUSION:

Poor correlation between CF and the distance of mapping points from the 3D map surfaces and electrogram information shows the limitation of 3D mapping and electrogram information for predicting good contact. In addition, mapping seems to require far less CF than ablation requires.

Videos

MEMBERSHIP CATEGORIES AND GUIDELINES

  • Members - Full time life members with voting rights: All those with DM/DNB cardiology qualification or equivalent and interest in arrhythmia/EP : Fees Rs 10,000.
  • Associate Members - DM/DNB/Fellows during training period. Fees Rs 3,000. No voting rights.
  • International Members: Overseas doctors with appropriate qualification and interest in arrhythmias. No voting rights. Fees 300$.
  • Industry members: Industry personnel associated with arrhythmology can become members. Membership is non-transferable. No voting rights. Fees 25,0000.
  • Any Associate Members who become eligible for Full time life membership (on completion of training period), need to pay only the balance of Rs 7,000 (10,000 - 3,000) if this is one within 1 year after completion of training. If the application for Full time life membership is received after expiry of one year of their entry as Associate Members, the full fees (viz Rs 10,000) shall apply.
  • Membership application need to be endorsed by two IHRS Members.
  • The application forms received by the office of Vice President, IHRS would need to be finally approved by the credentialing Committee (comprising of President, Secretary and Joint Secretary, IHRS).

Please print this form and send appropriate DD/Cheque in favour of Indian Heart Rhythm Society, and send through post to the following Address:

Dr Anil Saxena
Director, Cardiac Pacing & Electrophysiology
Fortis Escorts Heart Institute
Okhla Road, New Delhi, 110025 INDIA
Vice President, Indian Heart Rhythm Society
Mobile: +91 9810025511
Email: anil.saxena@hotmail.com
Secretary: +91 9910665566 (Ms Kumkum Sharma)